QUESTION

I am using the Silicon Labs C8051F020 and the Keil CA51 V7.00 and RTX51 V.700. What are the Device Type Number and Timer that I need to set in the RTX Configuration?

ANSWER

RTX51 Version 7.00 supports the following Processor Types for the Silicon Labs devices. Note that you may use Timer 0 or Timer 1 but Timer 2 is not supported as a system timer.

Cygnal Device       CPU Number
------------------------------
C8051F005/6/7       39 [*2]
C8051F015/16/17     39 [*2]
C8051F020/21/22/23  43 [*2]
C8051F206           40 [*2]
C8051F226           40 [*2]
C8051F236           40 [*2]
------------------------------

[*2] Timer 2 not supported as System Timer