MCB950: FS2 Debugger does not connectInformation in this article applies to:
QUESTIONI have an MCB950 Board, but I cannot to connect to the JTAG interface using the FS/2 debugger. What could be wrong? ANSWERThere was a series of boards manufactured, where the value of R4 and R10 are swapped. Make sure that the value of R4 is 10KOhm and R10 is 0 Ohm. Also, you need to enable the 2-wire debug port with a configuration setting in the Philips P89LPC952 or P89LPC954 device. This can be configured using the ISP utility FlashMagic. Open the dialog ISP - Device and set the following:
Then change the jumper settings on MCB950 board back to RUN mode (RESET = OFF, RUN = ON). When connecting with the FS2 debugger, make sure you select the FS2DI cable. MORE INFORMATION