For Infineon XC164CM-16F — Timer Block GPT2 (T5, T6)
Simulation support for this peripheral or feature is comprised of:
- Dialog boxes which display and allow you to change peripheral configuration.
These simulation capabilities are described below.
Timer/Counter 5 Dialog
The Timer/Counter 5 dialog allows you to view and change the SFRs
associated with Timer/Counter 5. This timer/counter is a general
purpose unit which may be used for timing, counting, and so on.
-
Mode contains the operating mode and the input selector
for the timer.
Direction
-
T5UDE (External Up/Down Enable) is set to let T5EUD
control direction.
-
T5EUD (External Up/Down Control Input) when T5UDE is
set, this external input controls the count direction.
-
T5UD is the timer up/down control. It can also reverse
the count direction selected in T5EUD, when T5UDE is set.
-
Direction displays whether the timer/counter counts up
or down.
Capture
-
Capture (Input Edge Selection) selects the pin and
signal transition that determines how a capture event is
triggered.
-
T5SC (Timer 5 Capture Mode Enable) is set to allow
capture mode for Timer 5.
-
CAPIN is input pin used for triggering a capture
event.
-
CAPREL (Capture/Reload Register) contains the
capture/reload value.
-
CRIR (Capture Interrupt Request Flag) is set when a
capture event occurs.
-
T5CLR (Timer 5 Clear Enable Bit) is set to clear Timer 5
when a capture event occurs.
-
T5CC (Timer 5 Capture Correction) is set to decrement
Timer 5 prior to the capture event.
Status
- Status displays the current status of the timer.
-
T5 contains the value of the T5 SFR which is the current
timer value or count.
-
T5CON contains the value of the T5CON SFR which is the
current configuration for Timer 5.
-
T5R (Timer 5 Run Flag) is set when Timer 5 is
running.
-
T5RC (Timer 5 Remote Control) is set to control Timer 5
from The Timer 6 run flag (T6R) instead of T5R.
- T5IN is the Timer 5 External Input pin.
-
T5IR (Timer 5 Interrupt Request Flag) is set when the
Timer 5 overflows.
Timer/Counter 6 Dialog
The Timer/Counter 6 dialog allows you to view and change the SFRs
associated with Timer/Counter 6. This timer/counter is a general
purpose unit which may be used for timing, counting, and so on.
-
Mode contains the operating mode and the input selector
for the timer.
Direction
-
T6UDE (External Up/Down Enable) is set to let T6EUD
control direction.
-
T6EUD (External Up/Down Control Input) when T6UDE is
set, this external input controls the count direction.
-
T6UD is the timer up/down control. It can also reverse
the count direction selected in T6EUD, when T6UDE is set.
-
Direction displays whether the timer/counter counts up
or down.
Block Prescaler
-
BPS2 (Block Prescaler Control) selects the clock divider
(2, 4, 8 or 16) for the general purpose core timer(GPT2).
Output
-
T6OTL (Overflow Toggle Latch) toggles when Timer 6
overflows or underflows.
-
T6OE (Overflow/Underflow Output Enable) is set to output
the state of the Timer 6 toggle latch (T6OTL) on output pin
T6OUT.
-
T6OUT (Timer 6 Output Pin) contains the state of the the
Timer 6 output pin.
Status
- Status displays the current status of the timer.
-
CAPREL (Capture/Reload Register) contains the
capture/reload value.
-
T6 contains the value of the T6 SFR which is the current
timer value or count.
-
T6CON contains the value of the T6CON SFR which is the
current configuration for Timer 6.
-
T6R (Timer 6 Run Flag) is set when Timer 6 is
running.
- T6IN is the Timer 6 External Input pin.
-
T6CLR (Timer 6 Clear Enable Bit) is set to clear Timer 6
when a capture event occurs.
-
T6IR (Timer 6 Interrupt Request Flag) is set when the
Timer 3 overflows.
-
T6SR (Timer 6 Reload Mode Enable) is set to allow
capture/reload mode for Timer 6.
-
CRIR (Capture Interrupt Request Flag) is set when a
capture event occurs.
|
|