Peripheral SimulationFor Infineon XE164G-48F — Capture/Compare Unit CAPCOM2 with T7 and T8 (P1H.4-7 Inputs Only) Simulation support for this peripheral or feature is comprised of:
These simulation capabilities are described below. CAPCOM 2 Unit Dialog
The CAPCOM 2 Unit dialog allows you to view and interactively configure the sixteen channels of the Capture/Compare Unit 2. Typically, your embedded program writes values to SFRs to configure the CAPCOM Unit and the CAPCOM channels. You may use this dialog to view and confirm the CAPCOM settings.
Timer/Counter 7 Dialog
The Timer/Counter 7 dialog allows you to view and change the SFRs associated with Timer/Counter 7. This timer/counter is used to generate the time base for the Capture/Compare units of the MCU.
Timer/Counter 8 Dialog
The Timer/Counter 8 dialog allows you to view and change the SFRs associated with Timer/Counter 8. This timer/counter is used to generate the time base for the Capture/Compare units of the MCU.
| ||||||||||
|