For Infineon XC164GM-16F — Timer Block GPT1 (T2, T3, T4)
Simulation support for this peripheral or feature is comprised of:
- Dialog boxes which display and allow you to change peripheral configuration.
These simulation capabilities are described below.
Timer/Counter 2 Dialog
The Timer/Counter 2 dialog allows you to view and change the SFRs
associated with Timer/Counter 2. This timer/counter is a general
purpose unit which may be used for timing, counting, and so on.
-
Mode contains the operating mode and the input selector
for the timer.
Direction
-
T2UDE (External Up/Down Enable) is set to let T2EUD
control direction.
-
T2EUD (External Up/Down Control Input) when T2UDE is
set, this external input controls the count direction.
-
T2UD is the timer up/down control. It can also reverse
the count direction selected in T2EUD, when T2UDE is set.
-
Direction displays whether the timer/counter counts up
or down.
Status
- Status displays the current status of the timer.
-
T2 contains the value of the T2 SFR which is the current
timer value or count.
-
T2CON contains the value of the T2CON SFR which is the
current configuration for Timer 2.
-
T2R (Timer 2 Run Flag) is set when Timer 2 is
running.
- T2IN is the Timer 2 External Input pin.
-
T2IR (Timer 2 Interrupt Request Flag) is set when the
Timer 2 overflows.
-
T2EDGE (Timer 2 Edge Detection Flag) is set when a count
edge is detected.
-
T2CHDIR (Timer 2 Count Direction Change Flag) is set
each time the count direction changes.
-
T2IRDIS (Timer 2 Interrupt Disable Flag) is set to
disable the Timer 2 Interrupt.
-
T2RDIR (Timer 2 Count Rotation Direction Flag) when set
Timer 2 counts up, when reset, Timer 2 counts down. This flag
controls direction when external up/down control (T2UDE) is not
enabled.
Timer/Counter 3 Dialog
The Timer/Counter 3 dialog allows you to view and change the SFRs
associated with Timer/Counter 3. This timer/counter is a general
purpose unit which may be used for timing, counting, and so on.
-
Mode contains the operating mode and the input selector
for the timer.
Direction
-
T3UDE (External Up/Down Enable) is set to let T3EUD
control direction.
-
T3EUD (External Up/Down Control Input) when T3UDE is
set, this external input controls the count direction.
-
T3UD is the timer up/down control. It can also reverse
the count direction selected in T3EUD, when T3UDE is set.
-
Direction displays whether the timer/counter counts up
or down.
Block Prescaler
-
BPS1 (Block Prescaler Control) selects the clock divider
(4, 8, 16 or 32) for the general purpose core timer(GPT1).
Output
-
T3OTL (Overflow Toggle Latch) toggles when Timer 3
overflows or underflows.
-
T3OE (Overflow/Underflow Output Enable) is set to output
the state of the Timer 3 toggle latch (T3OTL) on output pin
T3OUT.
-
T3OUT (Timer 3 Output Pin) contains the state of the the
Timer 3 output pin.
Status
- Status displays the current status of the timer.
-
T3 contains the value of the T3 SFR which is the current
timer value or count.
-
T3CON contains the value of the T3CON SFR which is the
current configuration for Timer 3.
-
T3R (Timer 3 Run Flag) is set when Timer 3 is
running.
- T3IN is the Timer 3 External Input pin.
-
T3IR (Timer 3 Interrupt Request Flag) is set when the
Timer 3 overflows.
-
T3EDGE (Timer 3 Edge Detection Flag) is set when a count
edge is detected.
-
T3CHDIR (Timer 3 Count Direction Change Flag) is set
each time the count direction changes.
-
T3RDIR (Timer 3 Count Rotation Direction Flag) when set
Timer 3 counts up, when reset, Timer 3 counts down. This flag
controls direction when external up/down control (T3UDE) is not
enabled.
Timer/Counter 4 Dialog
The Timer/Counter 4 dialog allows you to view and change the SFRs
associated with Timer/Counter 4. This timer/counter is a general
purpose unit which may be used for timing, counting, and so on.
-
Mode contains the operating mode and the input selector
for the timer.
Direction
-
T4UDE (External Up/Down Enable) is set to let T4EUD
control direction.
-
T4EUD (External Up/Down Control Input) when T4UDE is
set, this external input controls the count direction.
-
T4UD is the timer up/down control. It can also reverse
the count direction selected in T4EUD, when T4UDE is set.
-
Direction displays whether the timer/counter counts up
or down.
Status
- Status displays the current status of the timer.
-
T4 contains the value of the T4 SFR which is the current
timer value or count.
-
T4CON contains the value of the T4CON SFR which is the
current configuration for Timer 4.
-
T4R (Timer 4 Run Flag) is set when Timer 4 is
running.
- T4IN is the Timer 4 External Input pin.
-
T4IR (Timer 4 Interrupt Request Flag) is set when the
Timer 4 overflows.
-
T4EDGE (Timer 4 Edge Detection Flag) is set when a count
edge is detected.
-
T4CHDIR (Timer 4 Count Direction Change Flag) is set
each time the count direction changes.
-
T4IRDIS (Timer 4 Interrupt Disable Flag) is set to
disable the Timer 4 Interrupt.
-
T4RDIR (Timer 4 Count Rotation Direction Flag) when set
Timer 4 counts up, when reset, Timer 4 counts down. This flag
controls direction when external up/down control (T4UDE) is not