ULINK: Event Statistics Window shows unknown Energy valueInformation in this knowledgebase article applies to:
SYMPTOMWhen using ULINKplus with Power Measurement turned-on, the µVision Event Statistics window usually shows the electric charge, the current and the voltage for each execution slot. In some cases, only Q=unknown is shown instead of these values.
CAUSEOne reason might be that µVision does not have correct timestamps to measure the power consumption for the execution slots. This may happen if the Event Recorder RAM buffer is not located in non-initialized memory. RESOLUTIONLocate the Event Recorder RAM buffer into non-initialized RAM as described in the µVision manual (step 5). MORE INFORMATION