|
|
Home / µVision User's Guide C51, C251, C166 Development Tools
Command Line
µVision can be invoked from a command line to build a project,
start the debugger, or download a program to Flash. The command
applies to project and multiple-project files:
UV4 〚command〛 〚projectfile〛 〚options〛
Where
command |
is one of the commands listed below. If no command is
specified, µVision opens the project file in interactive Build
Mode. |
projectfile |
is the name of a project file. µVision project files have
the extension .uvproj, multiple-project files the
extension .uvmpw. If no project file is specified,
µVision opens the project file used last. |
options |
are additional parameters that specify the project target
name or output file. |
The following commands are available:
Command |
Description |
-b |
Builds the last current target of a project and
exits after the build process finished. Refer to option
-t to change the target. For multi-projects, the command
builds the targets as defined in the dialog Project - Batch
Build.
Examples:
UV4 -b PROJECT1.uvprojx |
-c |
Clean all project targets of a project. For a
multi-project, the command cleans all targets that have been
selected in the dialog Project - Batch
Build. Refer to the note on Project Menu and Commands for
details about the cleaning process.
Examples:
UV4 -c PROJECT1.uvprojx |
-cr |
Clean all project targets and re-translate the
last current target of a project. Refer to option -t to
change the target. For multi-projects, the command cleans all
targets and re-translates the targets as selected in the dialog
Project -
Batch Build. Refer to the note on Project Menu and Commands for
details about the cleaning process.
Examples:
UV4 -cr PROJECT1.uvprojx |
-d |
Starts µVision in Debugging Mode. Use this
command together with a debug initialization file to execute
automated test procedures. Exit the debugging session with the
EXIT command.
Examples:
UV4 -d PROJECT1.uvprojx |
-f |
Downloads the program to Flash and exits after
the download process finished.
Examples:
UV4 -f PROJECT1.uvprojx -t"MCB2100 Board" |
-r |
Re-translates the last current project target
and exits after the build process finished. Refer to option
-t to change the target. For multi-projects, the command
re-translates the targets as defined in the dialog Project - Batch
Build.
Examples:
UV4 -r PROJECT1.uvprojx -t"Simulator" |
The following options can be used:
Option |
Description |
-j0 |
Hides the µVision GUI. Messages are suppressed.
Use this option for batch testing. |
-i import_file.xml |
Creates a new project or updates an existing
project using the data provided by an XML file, which has to be
compliant to the schema project_import.xsd available in
the directory ..\UV4. The target name can be specified
with the option -t. By default, the target name is set
to the device name. The GUI is suppressed automatically when
using this option.
Examples:
UV4 MyProject.uvprojx –i MyImport.xml |
-n device_name |
Creates a new project with the specified
device_name. The target name can be specified with the
option -t. By default, the target name is set to the
device name. The GUI is suppressed automatically when using
this option.
Examples:
UV4 MyProject.uvprojx –n Device1234
UV4 MyProject.uvprojx –i MyImport.xml –n Device5678 -t
FlashDebug |
-t targetname |
Sets targetname as the current target. If
not specified, then the last known target is used.
Examples:
UV4 -r PROJECT1.uvprojx -t"MCB2100 Board" |
-o outputfile |
Specifies the output log file.
Examples:
UV4 -r PROJECT1.uvprojx -o"listmake.prn"
UV4 -r "C:\MyProjects\ARM\Example-mpw.uvmpw" -o
"c:\temp\log.txt" |
-q |
Re-builds the selected targets of a
multiple-project. Ensure that each target has another object
output folder. Use the menu Projects - Options for Target
- Output - Select Folder for Objects.
Examples:
UV4 -r "C:\MyProjects\ARM\Example-mpw.uvmpwx" -q -o
"c:\temp\log.txt" |
-z |
Re-builds all targets of a project or
multiple-project. Ensure that each target has another object
output folder. Use the menu Projects - Options for Target
- Output - Select Folder for Objects.
Examples:
UV4 -b PROJECT1.uvproj -z -o "c:\temp\log.txt"
UV4 -b "C:\MyProjects\ARM\Example-mpw.uvmpwx" -q -z -o
"c:\temp\log.txt" |
-x |
Enables DDE mode and returns complete command
output. This option can be used only with the command
-d. |
-y |
Enables DDE mode and returns only command
confirmations. This option can be used only with the command
-d. |
µVision sets the ERRORLEVEL after each build process to
indicate the status. Refer to the Windows-help for information about
ERRORLEVEL. The values are listed below:
ERRORLEVEL |
Description |
0 |
No Errors or Warnings |
1 |
Warnings Only |
2 |
Errors |
3 |
Fatal Errors |
11 |
Cannot open project file for writing |
12 |
Device with given name in not found in
database |
13 |
Error writing project file |
15 |
Error reading import XML file |
Examples:
|
|